FA carbon monoxide detector

$134.74 / EA

LV-052 · MasterFormat 28 31 00 · EA

What’s in this rate

This unit is installing one system-monitored carbon monoxide detector on a 12/24 VDC fire or security circuit. The technician mounts the detector, lands power and alarm or trouble conductors, and leaves it ready for test. The rate is per detector. A smoke detector, a heat detector, and FACP programming are separate units.

Includes

  • System-monitored CO detector, 12/24 VDC, with sounder and trouble relay
  • Wall or ceiling mount
  • Land power, alarm, and trouble conductors
  • Small tools

Excludes

  • Smoke detector
  • Heat detector
  • FACP programming
  • CO replacement plate kits

Build-up

Labor 0.5 hr × $60.00 wage and burden
$30.00
Material and small tools
$81.35
Direct rate (labor, material, and tools)
$111.35 / EA
Overhead 10% of direct
$11.14
Fee 10% of (direct and overhead)
$12.25
Loaded rate
$134.74 / EA