RPZ detector-check backflow

$1,006.36 / EA

PL-217 · MasterFormat 22 11 00 · EA

What’s in this rate

This EA unit installs one representative 2-inch reduced-pressure-zone detector-check backflow assembly; the plumber sets, connects, supports, and commissions the assembly. DCVA, DCDA, RPDA, PVB, standard RPZ without detector, double-check, atmospheric vacuum breaker, and other size adjustments are separate units.

Includes

  • representative 2-inch RPZ detector-check backflow assembly
  • isolation valves share, test cocks, and mounting hardware
  • set, connect, support, and commission

Excludes

  • DCVA backflow assembly
  • DCDA backflow assembly
  • RPDA backflow assembly
  • pressure vacuum breaker
  • standard RPZ without detector
  • double-check assembly
  • atmospheric vacuum breaker
  • other size adjustments
  • after-hours work

Build-up

Labor 1.55 hr × $72.00 wage and burden
$111.60
Material and small tools
$720.10
Direct rate (labor, material, and tools)
$831.70 / EA
Overhead 10% of direct
$83.17
Fee 10% of (direct and overhead)
$91.49
Loaded rate
$1,006.36 / EA

Use this in a private library