Tankless water heater cost, electric 27 kW
$1,919.22 / EA
27 kW electric tankless water heater costs about $1,919.22 each installed. This is a published starting point and varies by region and job.
National average
Enter a 5-digit ZIP for local pricing.
Adjust labor, markup, and materials for your own bids in a private library. Free, no card required. Published rates stay public while your hours and quotes stay private. See Unit rate estimating software.
RES-SEO-14-05 · MasterFormat 22 33 00 · EA
What’s in this rate
This unit is replacing an existing tank water heater with one whole-house 27 kW electric tankless water heater at the existing location. The crew drains and removes the old tank, mounts the tankless unit, adds service valves and connectors to the existing water lines, runs three new 40-amp circuits from the existing panel, and starts the heater. It is priced each. A panel upgrade, longer circuit runs, and a recirculation loop are separate units.
Includes
- Drain and remove the existing tank water heater, and haul it away
- One EcoSmart ECO 27 whole-house 27 kW 240 V electric tankless water heater, mounted at the existing location
- A pair of brass tankless service valves and two 3/4 in stainless connectors to the existing water lines
- Three new 40 A 240 V circuits from the existing panel: three 40 A 2-pole breakers and three 25 ft runs of 8/2 NM-B
- Fill, purge, start, and test
- Small tools
Excludes
- Electrical panel or service upgrade (electrical-panel-upgrade-100a-to-200a)
- Circuit runs longer than 25 ft each
- The 199k gas tankless (tankless-water-heater-199k-gas)
- 50-gal tank replacements (live)
- Point-of-use under-sink units
- New plumbing or electrical rough-in at a new location
- Recirculation loop
- Expansion tank
- Permits
Related rates
What is a 27 kW electric tankless water heater?
A 27 kW electric tankless water heater heats water on demand with electric elements instead of storing it in a tank. In this rate the crew drains and removes the existing tank, mounts the tankless unit at the existing water-heater location, adds service valves and connectors to the existing water lines, runs three new 40-amp, 240-volt circuits from the existing panel, and starts the heater. It is priced each. A panel or service upgrade, new piping to a new location, and a recirculation loop are separate units.
Build-up
- Plumber, 4 hr × $59.00
- $236.00
- Electrician, 4 hr × $58.00
- $232.00
- Material and small tools
- $1,069.05
- Equipment, Haul-away
- $49.08
- Direct rate (labor, material, equipment, and tools)
- $1,586.13 / EA
- Overhead 10% of direct
- $158.61
- Fee 10% of (direct and overhead)
- $174.48
- Loaded rate
- $1,919.22 / EA
Worked extension: 1 EA × $1,919.22 = $1,919.22 loaded for 1 EA. Quantity is a worked extension.
Questions
How is an electric tankless different from the 199k gas tankless?
The electric unit uses heating elements and needs large dedicated electrical circuits, but no gas line or vent. The 199k gas tankless burns natural gas, needs a gas reconnect and a concentric vent, and runs on a small electrical connection. Each one has its own rate, so the right unit can be priced for the fuel the home already has.
Does this include an electrical panel upgrade?
No. This rate is built for an existing panel that already has the capacity and open spaces for three new 40-amp double-pole breakers. When the service or panel cannot carry the load, the 100-amp to 200-amp panel upgrade is a separate unit. The old water-heater circuit is retired, and the existing tank is drained and hauled away in this rate.